    Thanks so far everyone, I'll refresh this when I go to tackle this project this winter.
    "There are no finger prints under water."

  2. #12
    At least my tag is unmolested
    Join Date
    Oct 2010
    Location
    CANON CITY, CO
    Posts
    3,133

    Default

    No, the white is not a ground. Its a neutral which is not the same thing.
    Sayonara

  3. #13
    Witness Protection Reject rondog's Avatar
    Join Date
    Jul 2007
    Location
    Parker, CO
    Posts
    8,285
    Blog Entries
    1

    Default

    Quote Originally Posted by spqrzilla View Post
    No, the white is not a ground. Its a neutral which is not the same thing.
    Yeah no kidding! Holy Misinformation Batman!
    There's a lot more of us ugly mf'ers out here than there are of you pretty people!

    - Frank Zappa

    Scrotum Diem - bag the day!

    It's all shits and giggles until someone giggles and shits.....

  4. #14
    Say "Car RAMROD!" J's Avatar
    Join Date
    Sep 1983
    Location
    Westminster, CO
    Posts
    4,012

    Default

    This ^

    In some models, it can be thought of as a ground, but it is not. Even in modeling, it is a virtual ground, and not a true ground.

    Do not connect the ground of a circuit to neutral. Unless you want a sparky surprise from your metal waffle iron some day.
    --J
    My Feedback

    "Praise be to our prophet, John Moses Browning, who hath bestowed upon us the new testament of shooting. Delivered unto us, his disciples, on 29 March 1911 A.D."



  5. #15
    If I had a son he would look like....Ben SideShow Bob's Avatar
    Join Date
    Mar 2010
    Location
    SE Aurora
    Posts
    7,120

    Default

    Quote Originally Posted by J View Post
    This ^

    In some models, it can be thought of as a ground, but it is not. Even in modeling, it is a virtual ground, and not a true ground.

    Do not connect the ground of a circuit to neutral. Unless you want a sparky surprise from your metal waffle iron some day.

    Talking from experience there J ?
    Bet you experienced the "Old Butter Knife in the toaster" too.......
    My T.P. wheeling and dealing feedback is here.

    Opinions are like assholes, everybody has one, and it stinks more than mine.


    Yo Homie, That my chainsaw ?



    Pati, improbe et vince

  6. #16
    Paper Hunter
    Join Date
    Nov 2008
    Location
    Olympic peninsula of Washington
    Posts
    255

    Default

    According to the NEC, the white or neutral wire is the "grounded" wire and the green or bare wire is the "grounding" wire. They are not interchangeable.

  7. #17
    Say "Car RAMROD!" J's Avatar
    Join Date
    Sep 1983
    Location
    Westminster, CO
    Posts
    4,012

    Default

    Quote Originally Posted by SideShow Bob View Post
    Talking from experience there J ?
    Bet you experienced the "Old Butter Knife in the toaster" too.......
    Degree in Electrical engineering count? I've taken my share of zaps.

    Common is a virtual ground. 120V RMS AC can be ~ 240 on the up swing and be technically correct if neutral and down swing are proportionally offset1. Netural would still be way off of true ground. Extreme example, but shows how neutral is not a true ground.

  8. #18
    Gong Shooter mindfold's Avatar
    Join Date
    Jul 2012
    Location
    Aurora
    Posts
    347

    Default

    Neutral is for the transmission, ground is for safety. It is there so that you do not become the easiest path in the circuit.

  9. #19
    Paintball Shooter
    Join Date
    Dec 2015
    Location
    Pueblo West
    Posts
    33

    Default

    Quote Originally Posted by laportecharlie View Post
    According to the NEC, the white or neutral wire is the "grounded" wire and the green or bare wire is the "grounding" wire. They are not interchangeable.
    Correct, they are two different wires for different purposes. The grounded or neutral conductor white wire is what completes your circuit and is a current carrying conductor. The grounding, equipment grounding conductor or "ground" green or bare wire is to carry the current to ground in the event of a ground fault. There should never be any current on this unless there is a problem.

    To the OP what kind of wiring do you have? Is it a two wire cable (Romex)? Or single wires in conduit? Has your panel been upgraded or original? Do the white wires run to the ground block in attic you mentioned?
    Last edited by Colorado Fatboy; 12-22-2015 at 23:47.

  10. #20
    QUITTER Irving's Avatar
    Join Date
    Nov 2008
    Location
    Denver, CO
    Posts
    46,527
    Blog Entries
    1

    Default

    Going to updated panel. Old romex, but may be 3 wire. Looked around for grounding block and didn't see one. I'll post again when I can really get into the project.